06/03/19
Message Overview:
Fault Message:
CPC2 [NO DATA] /CPC1 /WRG
Fault Code:
2138324ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller (CPC) 2 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Cabin Pressure Controller (CPC) 2 does not receive the ARINC 429 signal from CPC1.
Possible Causes:
- Cabin Pressure Controller (CPC) 1 (A21)
- Cabin Pressure Controller (CPC) 2 (A22)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Cabin Pressure Controllers | AMM 21-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cabin Pressure Controllers | AMM 21-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks of the ARINC 429 wires going from CPC1 to CPC2.
- If wiring checks are good, continue with next step.
- If wiring checks are not good, repair defective wiring as required and do close out.
- Connect a datatrack in parallel with the ARINC 429 receive signal from CPC1 to CPC2 A22P1-44 (-) and A22P1-50 (+). If data track not available go to next step.
- If data is not received, replace CPC2 and do close out.
- If data is received, replace CPC1 and do close out.
- Replace CPC2, if problem is still present reinstall original CPC2 and install replacement CPC in the #1 position.
- Do close out.