Message Overview:
Message Name:
CPC2 DISCRETE INPUT WIRING
Message Code:
2138325ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller (CPC) 2 |
| System Description: | 21-31-00 - Cabin Pressure Control System |
| Schematic Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] - SSM 21-31-00-101 - Cabin Pressure Control System |
| Wiring Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] - WM 21-31-02-1 - Cabin Pressure Control System - Controller # 2 [ALL] [ Global Express ] [ G5000 ] [ Global XRS ] - WM 21-31-00-01 - Cabin Pressure Control System - Controller # 2 - [9004-9010] [.Global Express ] [ G5000 ] [ Global XRS ] - WM 21-31-00-02 - Cabin Pressure Control System - Controller # 2 - [9003-9011-9158] [ Global Express ] [ G5000 ] [ Global XRS ] - WM 21-31-00-03 - Cabin Pressure Control System - Controller # 2 - [9002] |
Message Description:
Cabin Pressure Controller (CPC) 2 does not recognize the pin programming.
Possible Causes:
- Cabin Pressure Controller 2 (CPC2) (A22)
- Ground Stud (GS138)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Standard Aircraft Configuration for Maintenance | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-801 |
| Aircraft Walkaround (for Maintenance) | [ G5000 ] [ Global Express ] [ Global XRS ] AMM12-00-00-867-802 |
| Removal of the Cabin Pressure Controllers | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-31-01-000-801 |
| Installation of the Cabin Pressure Controllers | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-31-01-400-801 |
| Operational Test of the Cabin-Pressure-Controller Pressure Sensors | [ G5000 ] [ Global Express ] [ Global XRS ] AMM21-31-01-710-801 |
| Connect Electrical Power to the Aircraft | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-861-801 |
| Electrical/Electronic Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-801 |
| Electrostatic Discharge Safety Precautions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM24-00-00-910-802 |
| CAIMS PMAT General Instructions | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-801 |
| Access to Active Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-802 |
| Access to Stored Faults | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-803 |
| Access to System Diagnostics | [ G5000 ] [ Global Express ] [ Global XRS ] AMM45-45-00-970-804 |
Troubleshooting Recommendations:
- Perform wiring checks of the wire connected to A22P1-12.
- If wiring checks are good, go to step 4.
- If wiring checks are not good, repair as required and do the close out.
- Make sure GS138 is properly grounded.
- If GS138 is not properly grounded, repair as required and do close out.
- If GS138 is properly grounded, continue with the next step.
- Perform visual check of A22P1-13. Make sure there is no wire connected to pin 13. Pin 13 is used for CPC 1 position.
- If fault indication is gone, do close out.
- If fault remains, continue with the next step.
- Interchange CPC 2 with CPC 1.
- Does the fault follow the CPC?
- If YES, replace the CPC 2 and do close out.
- If NO, continue with the next step.
- Do close out.