02/16/21
Message Overview:
Message Name:
ACSC1 [CH A NO DATA] /DAU3 [B] /WRG
Message Code:
2161325ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 1 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Message Description:Air Conditioning System Controller (ACSC) 1 Channel A does not receive data from Data Acquisition Unit (DAU) #3.
Possible Causes:
- Data Acquisition Unit (DAU) 3 (A30)
- Air Conditioning System Controller (ACSC) 1 (A87)
- Junction Box (JB3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB3 | AMM 24-00-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 | AMM 24-00-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Turn CAIMS ACTIVE off (no Black Dot) in View/Environment menu, Red screen in cockpit should extinguish.
- Wait a few minutes for systems to stabilize.
- Refresh CAIMS Active Faults Screen. Is message clear?
- If YES, continue with the next step.
- If NO, go to step 5.
- Perform advisory wire (AW700-21-0160) "PACK FAULT" CAS Message While CAIMS is Active. Is fault message clear?
- If YES, do close out.
- If NO, continue with next step.
- Interchange DAU 3 with DAU 4. Is fault transferred or gone?
- If YES, replace the DAU 3 and do close out.
- If NO, continue with next step.
- Interchange ACSC 1 with ACSC 2. Is fault transferred or gone?
- If YES, replace ACSC 1 and do close out.
- If NO, continue with next step.
- Perform a wiring check between ACSC 1, DAU 3 and JB3. Is wiring check good?
- If NO, repair defective associated wiring and do close out.
- If YES, continue with next step.
- Perform a continuity check of JB3.
- If there is continuity, repair defective associated wiring as required and do close out.
- If there is no continuity, continue with next step.
- Replace JB3.
- Do close out.