background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/06/19

Message Overview:

Fault Message:

[ACSC1-A] LH A-I PRESS XDCR /WRG

Fault Code:

2161416ECS

Associated CAS:

L PACK FAULT
(Advisory)

Reporting LRU: Air Conditioning System Controller (ACSC) 1
System Description: 21-52-00
Schematic Diagram: 21-52-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Left Pack Anti-Ice Pressure Sensors has been detected out of range by Air Conditioning System Controller (ACSC) 1 Channel A.

Possible Causes:

  • Anti-Icing Pressure Sensor 1 (MT64)
  • Air Conditioning System Controller (ACSC) 1 (A87)
  • Junction Box (JB5)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)

Forum Articles/Infoservice/Newsletter: None

CAIMS has Pack Pressure XDCR. Data for ACSC controllers on all 4 channels. This will show sensor data and give you an idea of problem areas.

If CAIMS messages [ACSC1-A] LH PCK IN FLOW SENS/WRG, [ACSC1-A] LH PCK IN PRESS XDCR/WRG,[ACSC1-B] LH PCK IN FLOW SENS/WRG, and [ACSC1-A] LH PCK IN PRESS XDCR/WRG all shown, most possible cause is the SPDA 2 failure.

Quick Links:

Removal of the Anti-Icing Pressure Sensors AMM 21-52-41-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Anti-Icing Pressure Sensors AMM 21-52-41-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Air-Conditioning System Controllers AMM 21-60-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Air-Conditioning System Controllers AMM 21-60-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Junction Box JB5 AMM 24-00-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Junction Box JB5 AMM 24-00-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check CAIMS status of the Pack Anti-Ice Pressure Sensors (SYSTEM DIAG/21-00 AIR CONDITIONING/ACSC 1-A/LRU TEST/L ACSC CH. A PACK PRESSURE SENSOR DATA).
  2. Swap Pack Anti-Ice Pressure Sensor 1 with Pack Anti-Ice Pressure Sensor 2.

    1. If system checks are good, replace Pack Anti-Ice Pressure Sensor 1 and do close out.
    2. If fault remains, continue with next step.

  3. Perform a wiring checks between LH Pack Anti-Ice Pressure Sensor, JB5, ACSC 1 and Gnd.

    1. If the wiring checks are not good, replace the defective associated wiring and do close out.
    2. If the wiring checks are good, continue with next step.

  4. Swap ACSC 1 with ACSC 2.

    1. If system checks are good, replace ACSC 1 and do close out.
    2. If fault remains, continue with next step.

  5. Replace JB5.
  6. Do close out.