06/06/19
Message Overview:
Fault Message:
[ACSC1-A] LH A-I PRESS XDCR /WRG
Fault Code:
2161416ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 1 |
| System Description: | 21-52-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Left Pack Anti-Ice Pressure Sensors has been detected out of range by Air Conditioning System Controller (ACSC) 1 Channel A.
Possible Causes:
- Anti-Icing Pressure Sensor 1 (MT64)
- Air Conditioning System Controller (ACSC) 1 (A87)
- Junction Box (JB5)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter: None
CAIMS has Pack Pressure XDCR. Data for ACSC controllers on all 4 channels. This will show sensor data and give you an idea of problem areas.
If CAIMS messages [ACSC1-A] LH PCK IN FLOW SENS/WRG, [ACSC1-A] LH PCK IN PRESS XDCR/WRG,[ACSC1-B] LH PCK IN FLOW SENS/WRG, and [ACSC1-A] LH PCK IN PRESS XDCR/WRG all shown, most possible cause is the SPDA 2 failure.
Quick Links:
| Removal of the Anti-Icing Pressure Sensors | AMM 21-52-41-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Anti-Icing Pressure Sensors | AMM 21-52-41-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB5 | AMM 24-00-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB5 | AMM 24-00-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check CAIMS status of the Pack Anti-Ice Pressure Sensors (SYSTEM DIAG/21-00 AIR CONDITIONING/ACSC 1-A/LRU TEST/L ACSC CH. A PACK PRESSURE SENSOR DATA).
- Swap Pack Anti-Ice Pressure Sensor 1 with Pack Anti-Ice Pressure Sensor 2.
- If system checks are good, replace Pack Anti-Ice Pressure Sensor 1 and do close out.
- If fault remains, continue with next step.
- Perform a wiring checks between LH Pack Anti-Ice Pressure Sensor, JB5, ACSC 1 and Gnd.
- If the wiring checks are not good, replace the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Swap ACSC 1 with ACSC 2.
- If system checks are good, replace ACSC 1 and do close out.
- If fault remains, continue with next step.
- Replace JB5.
- Do close out.