Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/06/19

Message Overview:

Fault Message:

[ACSC1-A] LH CMP DIS TEMP SENS /WRG

Fault Code:

2161424ECS

Associated CAS:

L PACK FAULT
(Advisory)

Reporting LRU: Air Conditioning System Controller (ACSC) 1
System Description: 21-52-00
Schematic Diagram: 21-52-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-52-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Left Compressor Discharge Temperature Sensor has been detected out of range by Air Conditioning System Controller (ACSC) 1 Channel A.

Possible Causes:

  • Compressor Discharge Temperature Sensor 1 (E25)
  • Air Conditioning System Controller (ACSC) 1 (A87)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Compressor Discharge Temperature-Sensors AMM 21-52-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Compressor Discharge Temperature-Sensors AMM 21-52-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Air-Conditioning System Controllers AMM 21-60-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Air-Conditioning System Controllers AMM 21-60-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Access CAIMS Systems Diagnostics wih pack off and cold, verify if data is valid and compare with opposite side.

    1. If data is valid, go to step 3.
    2. If data is not valid, continue with next step.

  2. Swap Compressor Discharge Temperature Sensor 1 with Compressor Discharge Temperature Sensor 2.

    1. If system checks are good, replace Compressor Discharge Temperature Sensor 1 and do close out.
    2. If fault remains, continue with next step.

  3. Perform a wiring checks between Compressor Discharge Temperature Sensor and ACSC 1.

    1. If the wiring checks are not good, replace the defective associated wiring and do close out.
    2. If the wiring checks are good, continue with next step.

  4. Replace ACSC 1.
  5. Do close out.