Message Overview:
Fault Message:
[ACSC1-A] LH MIX-MANI TEMP SENS/WRG
Fault Code:
2161426ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 1 |
| System Description: | 21-20-00 |
| Schematic Diagram: | 21-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Left Mix Manifold Temperature-Sensors has been detected out of range by Air Conditioning System Controller (ACSC) 1 Channel B.
Possible Causes:
- Mix Manifold Temperature Sensor (MIXTS) 1 (E24)
- Air Conditioning System Controller (ACSC) 1 (A87)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter:
CAIMS has Pack Temp. Sensor Data for ACSC controllers on all 4 channels. This will show sensor data and give you an idea of problem areas, even with the air system not operating, but power is on.
Quick Links:
| Removal of the Mix Manifold Temperature-Sensors | AMM 21-21-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Mix Manifold Temperature-Sensors | AMM 21-21-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap Mix Manifold Temperature Sensor 1 with Mix Manifold Temperature Sensor 2.
- If system checks are good, replace Mix Manifold Temperature Sensor 1 and do close out.
- If fault remains, continue with next step.
- Perform a wiring checks between Mix Manifold Temperature-Sensors and ACSC 1.
- If the wiring checks are not good, replace the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Replace ACSC 1.
- Do close out.