Message Overview:
Fault Message:
[ACSC1-B] LH TEMP CONT VLV CMD /TCV
Fault Code:
2162320ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 1 |
| System Description: | 21-52-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-52-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Temperature Control Valve 1 position does not agree with the Air Conditioning System Controller (ACSC) 1 command.
Possible Causes:
- Temperature Control Valve 1 (L23)
- Air Conditioning System Controller (ACSC) 1 (A87)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express - 9002 to 9153 and Global 5000 - 9127 to 9411, 9417 to 9431, 9998 and Global Express XRS - 9159 to 9429)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Temperature Control Valves | AMM 21-52-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Temperature Control Valves | AMM 21-52-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between Temperature Control Valve and ACSC 1.
- If wiring check are not good, repair the defective associated wiring and do close out.
- If wiring check are good, continue with next step.
- Swap Temperature Control Valve 1 with Temperature Control Valve 2.
- If system checks are good, replace Temperature Control Valve 1 and do close out.
- If fault remains, continue with next step.
- Replace ACSC 1.
- Do close out.