06/10/19
Message Overview:
Fault Message:
AIR CONDITIONING SYS CONT #1 CH B
Fault Code:
2162329ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 1 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-60-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Air Conditioning System Controller (ACSC) 1 internal failure, or faulty wiring.
Possible Causes:
- Air Conditioning System Controller (ACSC) 1 (A87)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - (9002 to 9312, 9314 to 9380, 9384 to 9429) and Global 5000 - (9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998))
Forum Articles/Infoservice/Newsletter:
Ensure cannon plugs are clean and all pins and sockets intact and secure. Check the drag on the appropriate sockets for continuity.
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks at ACSC 1 including 28 Volts at A87P1-44, A87P1-75 and GND at A87P1-32, A87P1-54 and A87P1-65.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Re-Rack ACSC 1.
- Replace ACSC 1.
- Do close out.