06/10/19
Message Overview:
Fault Message:
[ACSC1-B] LH PCK DIS TEMP SENS /WRG
Fault Code:
2162422ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 1 |
| System Description: | 21-52-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-52-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Left Pack Discharge Temperature-Sensors has been detected out of range by Air Conditioning Controller (ACSC) 1 Channel B.
Possible Causes:
- Air Conditioning System Controller (A87)
- Pack Discharge Temperature-Sensors (PDTS) 1 (E27)
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS/OMS is active (Global Express - (9002 to 9153), G5000 - (9127 to 9411, 9417 to 9431, 9998) and Global XRS - (9159 to 9429))
- AW700-45-0065 - CAIMS Nuisance Fault Messages (Global Express - (9002 to 9153), G5000 - (9127 to 9411, 9417 to 9431, 9998) and Global XRS - (9159 to 9429))
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Pack Discharge Temperature-Sensors | AMM 21-52-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pack Discharge Temperature-Sensors | AMM 21-52-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS. Check status of PDTS from the ACSC 1 and the DAU 1B. If both are reporting the PDTS defective, Continue to step 3.
- If only one component has reported the PDTS as defective, Swap the reporting component (DAU or ACSC) and perform step 1 again.
- Perform wiring checks between Pack Discharge Temperature Sensor and ACSC 1.
- If wiring checks are not good, repair associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between Pack Discharge Temperature Sensor and DAU 1.
- If wiring checks are not good, repair associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Replace PDTS 1.
- Do close out.