Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/10/19

Message Overview:

Fault Message:

[ACSC1-B] LH MIX-MANI TEMP SENS/WRG

Fault Code:

2162426ECS

Associated CAS:

L PACK FAULT
(Advisory)

Reporting LRU: Air Conditioning System Controller (ACSC) 1
System Description: 21-52-00
Schematic Diagram: 21-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Left Mix Manifold Temperature-Sensors has been detected out of range by Air Conditioning Controller (ACSC) 1 Channel B.

Possible Causes:

  • Air Conditioning System Controller (ACSC) 1 (A87)
  • Mix Manifold Temperature Sensor 1 (E24)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Mix Manifold Temperature-Sensors AMM 21-21-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Mix Manifold Temperature-Sensors AMM 21-21-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Air-Conditioning System Controllers AMM 21-60-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Air-Conditioning System Controllers AMM 21-60-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap Mix Manifold Temperature-Sensor 1 with Mix Manifold Temperature-Sensor 2.

    1. If system checks are good, replace Mix Manifold Temperature-Sensor 1 and do close out.
    2. If fault remains, continue with next step.

  2. Perform wiring checks between Mix Manifold Temperature-Sensors and ACSC 1.

    1. If wiring checks are not good, repair the defective associated wiring and do close out.
    2. If wiring checks are good, continue with next step.

  3. Replace ACSC 1.
  4. Do close out.