06/11/19
Message Overview:
Fault Message:
ACSC2 [NO DATA FROM CH B TO CH A]
Fault Code:
2163316ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-60-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Loss of communication between the cards in Air Conditioning System Controller (ACSC) 2.
Possible Causes:
- Air Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express - 9002 to 9153 and Global 5000 - 9127 to 9411, 9417 to 9431, 9998 and Global Express XRS - 9159 to 9429)
- AW700-45-0065 - CAIMS Nuisance Fault Messages (Global Express - 9002 to 9153 and Global 5000 - 9127 to 9411, 9417 to 9431, 9998 and Global Express XRS - 9159 to 9429)
Forum Articles/Infoservice/Newsletter:
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Verify this is an active fault Ref. AW700-21-0160 "PACK FAULT" CAS Message While CAIMS is Active.
- Replace ACSC 2.
- Do close out.