Message Overview:
Fault Message:
ACSC2 [CH A NO DATA] /DAU4 [B] /WRG
Fault Code:
2163325ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) No. 2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-08 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Air Conditioning System Controller (ACSC) 2 Channel A does not receive data from Data Acquisition Unit (DAU) 4.
Possible Causes:
- Air Conditioning System Controller (ACSC) 2 (A88)
- Data Acquisition Unit (DAU) 4 (A31)
- Junction Box (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap DAU 4 with DAU 3.
- If the system checks are good, replace DAU 4 and do close out.
- If the fault remains, continue with next step.
- Swap ACSC 2 with ACSC 1.
- If the system checks are good, replace ACSC 2 and do close out.
- If the fault remains, continue with next step.
- Perform a wiring checks of wires between DAU 4 and ACSC 2 (ref: Wiring Manual 31-42-00 Sheet 8 of 9, page 1).
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Remove JB4 and check K26 operation.
- Perform continuity check of JB4 (Ref: Wiring Manual: 31-42-00 Sheet 8 of 9, page 1).
- If there is continuity, repair the defective associated wiring as required and do close out.
- If there is no continuity, continue with next step.
- Replace JB4.
- Do close out.