Message Overview:
Fault Message:
ACSC2 [CH A NO DATA] /BMC2 /WRG
Fault Code:
2163328ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-20-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 36-11-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Air-Conditioning System Controller (ACSC) 2 Receiver Channel A does not receive data from Bleed Management Controller (BMC) 2.
Possible Causes:
- Air-Conditioning System Controller (ACSC) 2 (A88)
- Bleed Management Controller (BMC) 2 (A70)
- Junction Box (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap ACSC 2 with ACSC 1.
- If the system checks are good, replace ACSC 2 and do close out.
- If the fault remains, continue with next step.
- Swap BMC 2 with BMC 1.
- If the system checks are good, replace BMC 2 and do close out.
- If the fault remains, continue with next step.
- Perform a wiring check between ACSC 2 and BMC 2 (ref: Wiring Manual: 36-11-00 Sheet 2 of 12 Page 2).
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Perform a continuity check of JB4 (ref Wiring Manual: 36-11-00 Sheet 2 of 12 Page 2).
- If there is continuity, repair the defective associated wiring as required and do close out.
- If there is no continuity, continue with next step.
- Replace JB4.
- Do close out.