06/12/19
Message Overview:
Fault Message:
[ACSC2-A] RH PNEU THERMO CMD /THC
Fault Code:
2163421ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Air-Conditioning System Controller (ACSC) 2 has detected a failure with the Right Pneumatic Temperature Thermostat (THC).
Possible Causes:
- Pneumatic Temperature Thermostat 2 (S13)
- Air-Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Temperature Control Thermostat | AMM 36-11-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Temperature Control Thermostat | AMM 36-11-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap Right THC with Left THC.
- If system checks are good, replace Right THC and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between ACSC 2 and the THC.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Replace ACSC 2.
- Do close out.