06/12/19
Message Overview:
Fault Message:
ACSC2 [CH B NO DATA] /DAU4 [A] /WRG
Fault Code:
2164326ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-08 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Air Conditioning System Controller (ACSC) 2 Channel B does not receive data from Data Acquisition Units (DAU) 4.
Possible Causes:
- Air Conditioning System Controller 2 (A88)
- Data Acquisition Units (DAU) 4 (A31)
- Junction Box (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap DAU 4 with DAU 3.
- If the system check is good, replace DAU 3 and do close out.
- If the fault remains, continue with next step.
- Swap ACSC 2 With ACSC 1.
- If the system check is good, replace ACSC 2 and do close out.
- If the fault remains, continue with next step.
- Perform wiring checks of wires between JB4 and ACSC 2.
- If wiring checks are not good, repair associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Perform continuity check of JB4.
- If there is continuity, repair associated wiring and do close out.
- If there is no continuity, continue with next step.
- Replace JB4.
- Do close out.