06/13/19
Message Overview:
Fault Message:
[ACSC2-B] RH PRESS XDCR POWER /WRG
Fault Code:
2164429ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
A loss of the power source for the Pressure Transducers has been detected by Air Conditioning System Controller (ACSC) 2.
Possible Causes:
- Air Conditioning System Controller (ACSC) 2 (A88)
- Secondary-Power Distribution Assembly (SPDA) 4 (A16)
- Junction Box (JB6)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB6 | AMM 24-00-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB6 | AMM 24-00-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check for power at the A/Ice pressure sensor #2, the Pack Inlet Pressure Sensor #2, or the Pack Inlet Flow Sensor #2.
- If there is no power, go to step 3.
- If you have power at any of these, continue with next step.
- Swap ACSC 2 with ACSC 1.
- If system checks are good, replace ACSC 2 and do close out.
- If fault remains, continue with next step.
- Swap SPDA 4 with SPDA 2.
- If system checks are good, replace SPDA 4 and do close out.
- If fault remains, continue with next step.
NOTE 1: If SPDA 3 has been swapped with SPDA 4 a fault may have been transferred to another system on SPDA 2 ref Build 4 load lists with Pinout.xls.
NOTE 2: When swapping SPDAs, it is possible to loose your DC cabin feeds. Check the EMS-CDU Switch Control Page 3 under SYSTEM - CNTL button. First page is AC feeds 2nd and 3rd are DC feeds that will toggle off.
- Remove JB6 and perform wiring checks of all wiring / circuit involved with the sensors power source.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Perform continuity check of JB6.
- If there is continuity, repair the defective associated wiring as required and do close out.
- If there is no continuity, continue with next step.
- Replace JB6.
- Do close out.