Message Overview:
Fault Message:
ACSC2-AIRCRAFT CONFIG DISAGREE
Fault Code:
2172700ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-54-00 |
| Schematic Diagram: | 21-54-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-54-15 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The right Air Conditioning System Controller (ACSC) sees a mismatch between the pin programming of ACSC 1 and ACSC 2 regarding the aircraft type.
Possible Causes:
- Air Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS and check the pin programming as follow for both ACSCs to identify the affected side:
- System Diag
- 21-00 Air Conditioning
- Choose the Air Conditioning System Controller in which you want to verify the configuration
- LRU TEST
- CTRL PANEL & VALVE DATA
- Make sure the AIRCRAFT CONFIG is in accordance with the actual aircraft type for both ACSCs.
- If the AIRCRAFT CONFIG is in accordance with the actual aircraft type, do close out.
- If the AIRCRAFT CONFIG is NOT in accordance with the actual aircraft type, continue with next step.
- Perform a wiring checks between the following for the affected side:
For Left ACSC: Make sure that ground stud (GS1158) resistance is in accordance with AMM tolerances.From To Result A87P1-29 GS1158 For Right ACSC: Make sure that ground stud (GS1167) resistance is in accordance with AMM tolerances.
From To Result A88P1-29 GS1167 NOTE: Ground = 5000 and Open = GX / XRS
- If wiring and grounds are unserviceable, repair the defective associated wiring and do close out.
- If wiring and grounds are serviceable, continue with next step.
- Replace ACSC 2.
- Do close out.