background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/13/19

Message Overview:

Fault Message:

AFCS 1 INTERFACE FAULT

Fault Code:

2210002AF1

Associated CAS:

None

Reporting LRU: Automatic Flight Control System (AFCS) 1
System Description: 22-10-00
Schematic Diagram: 22-12-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 22-12-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Automatic Flight Control System (AFCS) 1 does not operate correctly.

Possible Causes:

  • Flight Guidance Control Panel (A79)
  • Integrated Avionics Computer (IAC) 1 (A11)
  • Integrated Avionics Computer (IAC) 2 (A10)
  • Integrated Avionics Computer (IAC) 3 (A12)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Integrated Maintenance Test (IMT) Fault Code Look-Up AMM 45-45-00-970-826 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Get access to system diagnostics on the CAIMS PMAT.
  2. Perform the IMT tests (Guidance Panel Test, Aileron Servo Test, Elevator Servo Test, Rudder Actuator Test, AFCS Switches Test, Elevator Trim Interface Test) for the active fault. After each IMT test has completed, check the TEST RESULTS page and record the fault type and code for the active IMT fault.
  3. Perform the IMT fault code look-up procedure to find the applicable troubleshooting procedures.
  4. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.