background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/20/19

Message Overview:

Fault Message:

APUGCU [LINE CURRENT SENSE]

Fault Code:

2420192LPS

Associated CAS:

None

Reporting LRU: Auxiliary Power Unit Generator Control Unit (APU GCU)
System Description: 24-22-00
Schematic Diagram: 24-22-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-22-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Auxiliary Power Unit Generator Control Unit (APU GCU) initiated Built-In Test has detected a failure with the Line Current internal sensing circuit.

Possible Causes:

  • Auxiliary Power Unit Generator Control Unit (APU GCU) (A109)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active faults page.

Quick Links:

Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove power from the A/C completely. Apply power to the A/C. Is the fault still present?

    1. If NO, monitor for failure and do close out.
    2. If YES, continue with next step.

  2. Replace APU GCU.
  3. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.