Message Overview:
Fault Message:
APUGEN ROTOR DIODE FAILURE
Fault Code:
2420199LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit Generator Control Unit (APU GCU) |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Auxiliary Power Unit Generator Control Unit (APU GCU) has detected a Rotor Diode in the APU GEN has failed or there is defective circuitry in the APU GCU, consequently resulting in APU Generator tripped off-line or not come on-line.
Possible Causes:
- Auxiliary Power Unit Generator Control Unit (APU GCU) (A109)
- Auxiliary Power Unit (APU) Generator (A110)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active faults page.