Message Overview:
Fault Message:
APUGCU GLC STATUS/SENSING FAULT
Fault Code:
2420231LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit Generator Control Unit (APU GCU) |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Auxiliary Power Unit Generator Control Unit (APU GCU) has detected a the Generator Line Contactor status/status sensing circuit fault, consequently resulting in the APU Generator tripped off-line or not come on-line.
Possible Causes:
- AC Power Center (ACPC) (A54)
- AC Power Center (ACPC) Generator Line Contactor (GLC) (K1)
- Auxiliary Power Unit Generator Control Unit (APU GCU) (A109)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active faults page.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) ZJC-Series Contactor (K1) | AMM 24-51-41-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) ZJC-Series Contactor (K1) | AMM 24-51-41-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Are there any other ACPC related CAIMS fault messages?
- If YES, troubleshoot them first.
- If NO, continue with next step.
- Swap APU GCU with GCU 2 (physically or using the GCU patch cable). Is the fault still present?
- If NO, replace APU GCU and do close out.
- If YES, continue with next step.
- Access ACPC Primary assembly. Disconnect APULC Status relay (K28) contact A1.
- Disconnect APU GCU connector A109P2 and do a continuity check as follows:
From To Result A109P2-19 Ground - If there is continuity, locate the location of the short circuit to ground. Repair defective wiring or replace ACPC if the short circuit is inside the ACPC and do close out.
- If there is no continuity, continue with next step.
- Do a continuity check between APU GCU and APULC Status relay as follows:
From To Result A109P2-19 K28-A1 - If there is no continuity, repair defective wiring as required or replace ACPC if open circuit is inside ACPC and do close out.
- If there is continuity, continue with next step.
- Replace APULC Status relay K28.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace APULC K1.
- Do close out.