Message Overview:
Fault Message:
APUGCU [31V INTL SPLY/SENSING]
Fault Code:
2420253LPS
Associated CAS:
| Reporting LRU: | Auxiliary Power Unit Generator Control Unit (APU GCU) |
| System Description: | 24-22-00 |
| Schematic Diagram: | 24-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Auxiliary Power Unit Generator Control Unit (APU GCU) has detected during continuous monitoring an internal failure related to the 31 Volts power supply which is either out of range or the sensing circuit is faulty.
Possible Causes:
- Auxiliary Power Unit Generator Control Unit (APU GCU) (A109)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active faults page.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove power from the A/C completely. Apply power to the A/C. Is the fault still present?
- If NO, monitor for failure and do close out.
- If YES, continue with next step.
- Replace APU GCU.
- Do close out.