Message Overview:
Fault Message:
GCU1 [OPEN CIRCUIT TR1]
Fault Code:
2421103LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) No. 1 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Generator Control Unit (GCU) #1 has detected a failure (open circuit) associated with Transistor 1 (TR1), consequently resulting in Generator #1 to tripped off-line or not come on-line.
Possible Causes:
- Generator Control Unit (GCU) 1 (A56)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Do a complete aircraft power reset. Is the fault still present?
- If YES, continue with next step.
- If NO, monitor for failure and do close out.
- Replace GCU 1.
- Do close out.