Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/25/19

Message Overview:

Fault Message:

GEN1 OPEN POR/FEED/GEN FAULT

Fault Code:

2421108LPS

Associated CAS:

GEN 1 FAIL
(Advisory)

Reporting LRU: Generator Control Unit (GCU) 1
System Description: 21-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Generator Control Unit (GCU) 1 has detected a failure (open circuit) associated with the Open POR/FEED/GEN circuit and consequently generator 1 trips off-line. Inhibited during Take-Off and Landing.

Possible Causes:

  • Generator Control Unit (GCU) 1 (A56)
  • Variable Frequency Generator (VFG) 1 (G1)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only)

The GCU NVMs can only be downloaded at position #2 or #3

Quick Links:

Removal of the Variable Frequency Generators (VFG) AMM 24-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Variable Frequency Generators (VFG) AMM 24-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap GCU 1 with GCU 2 (physically or using the GCU patch cable). Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace defective GCU.

  2. Disconnect connector A56P1 (GCU 1) and A54P6 (ACPC). Do a continuity checks as follow:

    From To Result
    A56P1-A Ground
    A56P1-B Ground
    A56P1-C Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  3. Do a continuity checks as follow:

    From To Result
    A56P1-A A54P6-A
    A56P1-B A54P6-B
    A56P1-C A54P6-C

    1. If there is continuity, continue with next step.
    2. If there is no continuity, repair defective wiring as required and do close out.

  4. Do a continuity checks as follow:

    From To Result
    VFG 1 stud T1 ACPC stud T1
    VFG1 Stud T2 ACPC stud T2
    VFG 1 Stud T3 ACPC stud T3

    1. If there is continuity, continue with next step.
    2. If there is no continuity, repair defective wiring as required and do close out.

  5. Disconnect ACPC studs T1, T2 and T3. Do a continuity checks as follow:

    From To Result
    VFG 1 stud T1 Ground
    VFG1 Stud T2 Ground
    VFG 1 Stud T3 Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  6. Do a continuity checks on the ACPC as follow:

    From To Result
    A54P6-A Ground
    A54P6-B Ground
    A54P6-C Ground

    1. If there is continuity, repair wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  7. Do a continuity checks on the ACPC as follow:

    From To Result
    A54P6-A ACPC stud T1
    A54P6-B ACPC stud T2
    A54P6-C ACPC stud T3

    1. If there is continuity, continue with next step.
    2. If there is no continuity, repair wiring as required and do close out.

  8. Swap VFG 1 with VFG 2. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace defective VFG.

  9. Replace ACPC.
  10. Do close out.