06/25/19
Message Overview:
Fault Message:
GCU1/ACPC/XFER INH SENS FAULT/SMOKE
Fault Code:
2421130LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 1 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) 1 has received a Generator Line Contactor (GLC) Inhibit (GLC INH) signal from the AC Power Center (ACPC) or has detected a failure in its internal GLC inhibit sensing circuit.
Possible Causes:
- Generator Control Unit (GCU) 1 (A56)
- AC Power Center (ACPC) (A54)
- Primary Logic Card (PLC) 1
- Primary Logic Card (PLC) 2
- Primary Logic Card (PLC) 3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only). The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 1 with GCU 2 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace GCU 1 and do close out.
- If fault remains, continue with next step.
- Remove PLC 1. Is the fault still present?
- If NO, install a new PLC in the 1 position and do close out.
- If YES, re-install PLC 1 and continue with next step.
- Remove PLC 2. Is the fault still present?
- If NO, install a new PLC in the 2 position and do close out.
- If YES, re-install PLC 2 and continue with next step.
- Remove PLC 3. Is the fault still present?
- If NO, install a new PLC in the 2 position and do close out.
- If YES, re-install PLC 2 and continue with next step.
- Remove PLC 1, PLC 2, PLC 3 and carry out a wiring checks on GCU 1. Disconnect GCU 1 connector A56P2 and using a multimeter, check for a ground short fault on A56P2-29.
- If a ground short fault is not detected, go to step 7.
- If a ground short fault is detected, continue with next step.
- On ACPC, disconnect connector A54P6. On connector A56P2, using a multimeter, check for a ground short fault on A56P2-29.
- If the ground short fault is no longer present, go to step 7.
- If the ground short fault is still present, repair or replace the wire harness between GCU 1 and the ACPC and do close out.
- Replace the ACPC.
- Do close out.