09/21/20
Message Overview:
Fault Message:
GCU1 [GLC DRIVE OPEN/SHORT/STATUS]
Fault Code:
2421133LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 1 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Line Contactor (GLC) 1 is detected faulty by the Generator Control Unit (GCU) 1.
Possible Causes:
- Generator Control Unit (GCU) 1 (A56)
- Contactor (K5)
- AC Power Center (ACPC) (A54)
- TB601
- TB101
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| AC Power Center Component Maintenance Manual | CMM 24-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 1 with GCU 2 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace GCU 1 and do close out.
- If fault remains, continue with next step.
- Swap Contactors K5 with K7.
- If system checks are good, replace K5 and do close out.
- If fault remains, continue with next step.
- Perform wiring check between ACPC and GCU 1.
- If wiring checks are good, continue with next step.
- If wiring checks are not good, repair defective wiring and do close out.
- Perform wiring check between TB101, TB601 and P103 in ACPC.
- If wiring checks are good, continue with next step.
- If wiring checks are not good, repair defective wiring and do close out.
- Replace ACPC.