Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/25/19

Message Overview:

Fault Message:

GCU1 [H/W OVERVOLTAGE SENSE FAULT]

Fault Code:

2421175LPS

Associated CAS:

GEN 1 FAIL
(Advisory)

Reporting LRU: Generator Control Unit (GCU) 1
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Generator Control Unit (GCU) 1 has detected a hardware over-voltage failure on initial power up, consequently preventing the generator to come on-line.

Possible Causes:

  • AC Power Center (ACPC) (A54)
  • Generator Control Unit (GCU) 1 (A56)
  • Variable Frequency Generators (VFG) 1 (G1)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).

The GCU NVMs can only be downloaded at position #2 or #3.

Quick Links:

Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Variable Frequency Generators (VFG) AMM 24-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Variable Frequency Generators (VFG) AMM 24-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. With connectors A56P1 (GCU 1) and G1P1 (VFG 1) disconnected, perform a check for a short circuit between G1P1-B and ground (See Quick Links: WIRING I/F-GCU1/VFG1).

    1. If a short to ground fault is detected, repair or replace wiring as required and do close out.
    2. If no short to ground fault is detected, go to next step.

  2. Swap GCU 1 with GCU 2 (or use the patch cable).

    1. After starting the engine, if the fault remains with GCU 1. Replace GCU 1 and do close out.
    2. If the fault moved to GCU 2, go to next step.

  3. Replace VFG #1.
  4. Do close out.