Message Overview:
Fault Message:
ACPC RS422 RECEIVE (GCU1) FAULT
Fault Code:
2421176LPS
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
AC Power Center (ACPC) senses a RS422 communication failure from the Generator Control Unit (GCU) 1.
Possible Causes:
- AC Power Center (ACPC) (A54)
- AC Power Center (ACPC) Primary Logic Card 3
- Generator Control Unit (GCU) 1 (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| AC Power Center Component Maintenance Manual | CMM 24-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
CAUTION: To prevent damage to the ACPC Mother Board connectors, ensure that the jumper wire pins outside diameter (OD) does not exceed 0.025 inch.
- Swap GCU 1 with GCU 2.
- If system checks are good, replace GCU 1 and do close out.
- If fault remains, continue with next step.
- Swap ACPC Primary Logic cards #3 with ACPC Primary Logic cards #2.
- If system checks are good, replace ACPC Primary Logic cards #3 and do close out.
- If fault remains, continue with next step.
- Perform wiring check between GCU#1, ACPC and P101.
- If system checks are good, repair wiring as required and do close out.
- If fault remains, continue with next step.
NOTE: Disconnect GCU#1 connector and remove ACPC PLC#3 to measure for short/open circuit.
- Replace ACPC.
- Do close out.