Message Overview:
Fault Message:
GEN1/GCU1 B PHASE PMG FAULT
Fault Code:
2421189LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 1 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) 1 senses a Permanent Magnet Generator (PMG) failure on phase B.
Possible Causes:
- Variable Frequency Generator (VFG) 1 (G1)
- Generator Control Unit (GCU) 1 (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Over current detection specification: output current is more than 185 Amps on at least one phase of the Generator #1.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 1 with GCU 2.
- If system checks are good, replace GCU 1 and do close out.
- If fault remains, continue with next step.
- Perform a wiring check between GEN#1 and GCU#1 as follows:
From To Result G1P1-C A56P1-F - If wiring checks are not good, repair wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace GEN 1.
- Do close out.