06/25/19
Message Overview:
Fault Message:
GEN1 SHORTED PMG FAULT
Fault Code:
2421191LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 1 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
A phase to phase short circuit on Variable Frequency Generator (VFG) 1 Permanent Magnet Generator has been detected by Generator Control Unit (GCU) continuous monitoring built-in test.
Possible Causes:
- Variable Frequency Generator (VFG) 1 (G1)
- Generator Control Unit (GCU) 1 (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU #1 with GCU #2 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace GCU 1 and do close out.
- If fault remains, continue with next step.
- Disconnect connector A56P1 (GCU 1) and G1P1 (VFG 1). Perform wiring checks (continuity = failure) between Main Generator and ground as follow:
From To Result G1P1-G Ground G1P1-C Ground G1P1-L Ground - If there is continuity, repair defective wiring as required and do close out.
- If fault remains, continue with next step.
- Replace VFG 1.
- Do close out.