06/24/19
Message Overview:
Fault Message:
GCU1 [ACPC CURRENT SIGNAL]
Fault Code:
2421194LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 1 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) initiated Built-In Test has detected a failure with the Load Current Signal sent to the Auxiliary Power Unit Full-Authority Digital Engine-Controller (FADEC) and the AC Power Center (ACPC).
Possible Causes:
- Generator Control Unit (GCU) 1 (A56)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active faults page.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove power from the A/C completely. Apply power to the A/C. Is the fault still present?
- If YES, continue with next step.
- If NO, monitor for failure and do close out.
- Replace GCU 1.
- Do close out.