06/25/19
Message Overview:
Fault Message:
GCU1 [MEF VOLTAGE SENSING]
Fault Code:
2421245LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 1 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) #1 has detected an internal failure related to the Main Exciter Field (MEF) voltage sensing circuit and, consequently resulting in a Generator #1 tripped off-line.
Possible Causes:
- Generator Control Unit (GCU) 1 (A56)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The GCU NVMs can only be downloaded at position #2 or #3.
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU4 and APU GCU into position 2 or 3 (for troubleshooting only).
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Replace the GCU 1.
NOTE: Use PMAT to monitor the fault on GCU. - Do close out.