Message Overview:
Fault Message:
GEN2 OVERFREQUENCY FAULT
Fault Code:
2422112LPS
Associated CAS:
| Reporting LRU: | Variable Frequency Generator (VFG) 2 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
An over-frequency failure signal is given when the line frequency of the Variable Frequency Generator (VFG) (Permanent Magnet Generator (PMG) frequency) is more than 629±1 Hz.
Possible Causes:
- Generator Control Unit (GCU) 2 (A57)
- Variable Frequency Generator (VFG) 2 (G2)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
NOTE:
- When generator is switched off, two reset attempts can be made. If NOT successful, reset will only be possible with a complete power cycle
- The frequency necessary to reset must be at least 5 Hz less than the frequency which caused the failure
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 2 with GCU 3 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace GCU 2 and do close out.
- If fault remains, continue with next step.
- Replace VFG 2.
- Do close out.