Message Overview:
Fault Message:
GEN2 DELTA CURRENT FAULT
Fault Code:
2422118LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 2 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Generator Control Unit (GCU) 2 detects between two phases a difference in output current larger than 35 A±5 A.
Possible Causes:
- AC Power Center (ACPC) (A54)
- Generator Control Unit (GCU) 2 (A57)
- Generator Line Contactor (GLC)
- Variable Frequency Generator (VFG) 2 (G2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Line Current Transformers | AMM 24-51-49-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Line Current Transformers | AMM 24-51-49-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check for CAIMS message related to the ACPC short circuit fault. Clear/troubleshoot the message first if existed.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap GCU 2 with GCU 3 (physically or using the GCU patch cable).
NOTE: Use PMAT to monitor the fault on GCU.- If system checks are good, replace GCU 2 and do close out.
- If fault remains, continue with next step.
- Disconnect T1, T2, T3 and G at VFG 2. Perform continuity check (closed circuit= failure) at the terminal block of VFG 2 as follows:
From To Result G2-T1 Ground G2-T2 Ground G2-T3 Ground - If there is continuity, go to step 20.
- If there is no continuity, continue with next step.
- Perform wiring checks (open circuit= failure) between VFG 2 and ACPC as follow:
From To Result G2-T1 ACPC VFG2-T4 G2-T2 ACPC VFG2-T5 G2-T3 ACPC VFG2-T6 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Disconnect connector G2P1 on the VFG 2. Perform continuity check (open circuit= failure) on VFG 2 as follow:
From To Result G2P1-F G2P1-D G2P1-E G2P1-D G2P1-J G2P1-D - If there is no continuity, go to step 20.
- If there is continuity, continue with next step.
- Perform continuity check (closed circuit= failure) on VFG 2 as follows:
From To Result G2P1-F Ground G2P1-E Ground G2P1-J Ground G2P1-D Ground - If there is continuity, go to step 20.
- If there is no continuity, continue with next step.
- Disconnect GCU 2 connector A57P2. Perform continuity check (open circuit= failure) between G2P1 and A57P2 as follows:
From To Result G2P1-F A57P2-41 G2P1-E A57P2-42 G2P1-J A57P2-50 G2P1-D A57P2-40 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform wiring checks (closed circuit= failure) between G2P1 and ground as follow:
From To Result G2P1-F Ground G2P1-E Ground G2P1-J Ground - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Disconnect ACPC connector A54P7. Perform continuity check (open circuit= failure) between A57P2 and A54P7 as follows:
From To Result A57P2-49 A54P7-E A57P2-57 A54P7-F A57P2-63 A54P7-G A57P2-62 A54P7-H - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform wiring checks (closed circuit= failure) between A57P2 and ground as follow:
From To Result A57P2-49 Ground A57P2-57 Ground A57P2-63 Ground - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform continuity check (open circuit= failure) between VFG 2 and K7 as follows:
From To Result G2-T1 K7-A3 G2-T2 K7-B3 G2-T3 K7-C3 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Repair wiring (including inside ACPC) between VFG 2 and K7 as follows:
From To Result G2-T1 K7-A3 G2-T2 K7-B3 G2-T3 K7-C3 - If fault remains, repair defective wiring as required and do close out.
- If system checks are good, continue with next step.
NOTE: Call Bombardier for decision to repair ACPC wiring or replace ACPC.
- Perform wiring checks (closed circuit= failure) between VFG 2 and ground as follow:
From To Result G2-T1 Ground G2-T2 Ground G2-T3 Ground - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- On current transducer 2 (LCTA 2), disconnect connector PL2. Perform continuity check (open circuit= failure) in ACPC between A54P7 and PL2 as follows:
From To Result A54P7-E PL2-1 A54P7-F PL2-2 A54P7-G PL2-3 A54P7-H PL2-4 - If there is no continuity, go to step 21.
- If there is continuity, continue with next step.
- Perform continuity check (open circuit= failure) in ACPC between A54P7 and ground as follows:
From To Result A54P7-E Ground A54P7-F Ground A54P7-G Ground - If there is continuity, go to step 21.
- If there is no continuity, continue with next step.
- Perform continuity check (open circuit= failure) at connector within PL2 as follows:
From To Result PL2-1 PL2-4 PL2-2 PL2-4 PL2-3 PL2-4 - If there is no continuity, go to step 18.
- If there is continuity, continue with next step.
- Perform continuity check (short circuit= failure) at connector between JL2 and ground as follows:
From To Result JL2-1 Ground JL2-2 Ground JL2-3 Ground - If there is no continuity, go to step 19.
- If there is continuity, continue with next step.
- Replace LCTA 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace GLC 2 (K7).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap VFG 2 with VFG 1.
- If system checks are good, replace VFG 2 and do close out.
- If fault remains, continue with next step.
- Replace ACPC.
- Do close out.