Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/25/19

Message Overview:

Fault Message:

GEN2 LINE CT OPEN/SHORT FAULT

Fault Code:

2422123LPS

Associated CAS:

GEN 2 FAIL
(Advisory)

Reporting LRU: Variable Frequency Generator (VFG) 2
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Variable Frequency Generator (VFG) 2 has tripped off-line or will not come on-line.

Possible Causes:

  • AC Power Center (ACPC) (A54)
  • Generator Control Unit (GCU) 2 (A57)
  • Line Current Transformer Assembly (LCTA)
  • Variable Frequency Generator (VFG) 2 (G2)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).

The GCU NVMs can only be downloaded at position #2 or #3.

Quick Links:

Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Line Current Transformers AMM 24-51-49-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Line Current Transformers AMM 24-51-49-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap GCU 2 with GCU 3 (physically or using the GCU patch cable).
    NOTE: Use PMAT to monitor the fault on GCU.

    1. If system checks are good, replace GCU 2 and do close out.
    2. If fault remains, continue with next step.

  2. Disconnect connector PL2 on LCTA 2.
  3. Perform continuity checks (open circuit = failure) within LCTA 2 as follow:

    From To Result
    PL2-1 PL2-4
    PL2-2 PL2-4
    PL2-3 PL2-4

    1. If there is continuity, go to step 5.
    2. If there is no continuity, continue with next step.

  4. Replace LCTA 2.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  5. Disconnect connector A57P2 (GCU 2).
  6. Perform continuity checks between GCU2 and LCTA2 as follow:

    From To Result
    A57P2-62 PL2-4
    A57P2-63 PL2-3
    A57P2-57 PL2-2
    A57P2-49 PL2-1

    1. If there is continuity, go to step 10.
    2. If there is no continuity, continue with next step.

  7. Disconnect connector A54P7 (ACPC).
  8. Perform continuity checks (open circuit = failure) between GCU 2 and A54P7 as follow:

    From To Result
    A57P2-62 A54P7-H
    A57P2-63 A54P7-G
    A57P2-57 A54P7-F
    A57P2-49 A54P7-E

    1. If there is continuity, go to step 12.
    2. If there is no continuity, continue with next step.

  9. Repair aircraft wiring between GCU 2 and ACPC as follows:

    From To Result
    A57P2-62 A54P7-H
    A57P2-63 A54P7-G
    A57P2-57 A54P7-F
    A57P2-49 A54P7-E

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.
      NOTE: Call Bombardier for decision to repair ACPC wiring or replace ACPC.

  10. Disconnect connector A54P7 (ACPC) and leave PL2 disconnected.
  11. Perform wiring checks (short circuit = failure) at connector A54P7 between pins H, G, F and E.

    1. If wiring checks are not good, repair wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  12. Replace ACPC.
  13. Do close out.