Message Overview:
Fault Message:
GCU2/ACPC/XFER INH SENS FAULT/SMOKE
Fault Code:
2422130LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 2 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) 2 has received a Generator Line Contactor (GLC) inhibit (GLC INH) signal from the AC Power Center (ACPC) or has detected a failure in its internal GLC inhibit sensing circuit.
Possible Causes:
- Generator Control Unit (GCU) 2 (A57)
- AC Power Center (ACPC) (A54)
- Primary Logic Card (PLC) 1
- Primary Logic Card (PLC) 2
- Primary Logic Card (PLC) 3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 2 with GCU 3.
- If system checks are good, replace GCU 2 and do close out.
- If the fault remains, continue with next step.
- Remove PLC 1.
- If system checks are good, install a new PLC in the #1 position and do close out.
- If the fault remains, re-install PLC 1 and continue with next step.
- Remove PLC 2
- If system checks are good, install a new PLC in the #2 position and do close out.
- If the fault remains, re-install PLC 2 and continue with next step.
- Remove PLC 3.
- If system checks are good, install a new PLC in the #3 position and do close out.
- If the fault remains, continue with next step.
- Remove PLC 1, PLC 2, PLC 3 and perform wiring checks for ground short fault.
- On GCU 2, disconnect connector A57P2 and using a multi-meter, check for a ground on A57P2-29.
- If the ground short fault is not detected, go to step 8.
- If the ground short fault is detected, continue with next step.
- On ACPC, disconnect connector A54P7 and on connector A57P2, using a multi-meter, check for a ground on A57P2-29.
- If the ground short fault is detected, repair or replace the defective wiring between GCU 2 and the ACPC and do close out.
- If the ground short fault is not detected, continue with next step.
- Replace the ACPC.
- Do close out.