Message Overview:
Fault Message:
GCU2 [GLCMON/GLCDMON SENSE]
Fault Code:
2422180LPS
| Reporting LRU: | Generator Control Unit (GCU) 2 |
| Associated CAS: | GEN 2 FAIL (ADVISORY) |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Generator Control Unit (GCU) internal monitoring detects a mismatch between the Generator Line Contactor (GLC) Drive signal voltage monitor and the GLC coil voltage monitor.
Possible Causes:
- Generator Control Unit (GCU) 2 (A57)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove power from the A/C completely. Apply power to the A/C. Is the fault still present?
- If NO, monitor for failure and do close out.
- If YES, continue with next step.
- Replace GCU 2.
- Do close out.