06/26/19
Message Overview:
Fault Message:
GEN3/GCU3 OIL LEVEL SNSE FAULT
Fault Code:
2423229LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 3 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Variable Frequency Generator (VFG) 3 remote oil level sensor or the Generator Control Unit (GCU) 3 sensing circuit is detected faulty by continuous Built−In Test (BIT) monitoring.
Possible Causes:
- Generator Control Unit (GCU) 3 (A58)
- Variable Frequency Generator (VFG) 3 (G3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active faults page.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect GCU 3 connector A58P2 and VFG 3 connector G3P1. Perform a continuity check as follows:
From To Result A58P2-33 Ground A58P2-60 Ground A58P2-33 A58P2-60 - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A58P2-33 Backshell (Shield) A58P2-60 Backshell (Shield) - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A58P2-33 G3P1-K A58P2-60 G3P1-M - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Swap the GCU 3 with GCU 4. Is the fault still present?
NOTE: Allow at least 8.5 minutes for the GCU to perform its self tests (2 samples).- If NO, replace GCU 3 and do close out.
- If YES, continue with next step.
- Replace VFG 3.
- Do close out.