Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

05/11/21

Message Overview:

Message Name:

GEN3 [LOW OIL LEVEL]

Message Code:

2423230LPS

Associated CAS:

None

Reporting LRU: Variable Frequency Generator (VFG) 3
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-03 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

Low oil level in Variable Frequency Generator (VFG) 3 is detected by the remote oil level sensing, consequently resulting in Generator 3 tripped off-line or not come on-line.

Possible Causes:

  • Generator Oil Level Sensor
  • Variable Frequency Generator (VFG) 3 (G3)
  • Generator Control Unit (GCU) 3 (A58)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter:

Notice To Operators (NTO): None

Flight Operation Notifications Manual (FONM): None

A GCU patch cable (GSE REF # 24X-24-02) can be used to interchange GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active faults page.

gcu_patch_cable

Quick Links:

Visual Check of the Variable Frequency Generator (VFG) Oil System AMM 24-12-00-210-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Variable Frequency Generators (VFG) AMM 24-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Variable Frequency Generators (VFG) AMM 24-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Quantity Check of the Main Generator Oil Supply AMM 24-25-00-610-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform a check of the oil quantity in VFG 3 and service if required as per AMM TASK 24-12-00-210-802 - Visual Check of the Variable Frequency Generator (VFG) Oil System. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  2. Disconnect GCU 3 connector A58P2 and VFG 3 connector G3P1. Perform a continuity check as follows:

    From To Result
    A58P2-33 Ground
    A58P2-60 Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  3. Perform a continuity check as follows:

    From To Result
    A58P2-33 G3P1-K
    A58P2-60 G3P1-M

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  4. Interchange the GCU 3 with GCU 4. Is the fault still present?

    1. If NO, replace GCU 3 and do close out.
    2. If YES, continue with next step.

  5. Replace VFG 3.
  6. Do close out.