Message Overview:
Fault Message:
GEN4 [PHASE NEUTRAL CROSSED]
Fault Code:
2424109LPS
Associated CAS:
| Reporting LRU: | Variable Frequency Generator (VFG) 4 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Variable Frequency Generator (VFG) 4 has tripped off-line or will not come on-line.
Possible Causes:
- Ground Stud (GS153)
- Generator Control Unit (GCU) 4 (A59)
- Variable Frequency Generator (VFG) 4 (G4)
- AC Power Center (ACPC) (A54)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
NOTE: The Generator ground stud connection may need to be visually inspected for signs of arcing.
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in CAIMS via the active fault page.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical Bonding - Adjustment/Test | SPM 51-80-00-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- At VFG 4, perform a check of the output connections at the terminal block. Are the connections as shown in the table below?
Connection Color T1 White T2 Blue T3 Orange G Green - If NO, reconnect or repair as required and do close out.
- If YES, continue with next step.
- At the ACPC, perform a check of the VFG input terminals at VFG 4 LCTA 4. Are the connections as shown in the table below?
Connection Color T1 White T2 Blue T3 Orange - If NO, reconnect or repair as required and do close out.
- If YES, continue with next step.
- Perform a bonding test of ground stud GS153 as follow:
From To Expected Result Result GS153 Ground <0.010 ohms - If the resistance value is higher than 0.010 ohms, repair ground stud and do close out.
- If the resistance value is good, continue with next step.
- Swap GCU 4 with GCU 3 (physically or using the GCU patch cable). Is the fault still present?
- If NO, replace GCU 4 and do close out.
- If YES, continue with next step.
- Disconnect GCU 4 connector A59P1 and ACPC connector A54P2. Perform a continuity check as follows:
From To Result A59P1-A Ground A59P1-B Ground A59P1-C Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A59P1-A A54P2-A A59P1-B A54P2-B A59P1-C A54P2-C - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Swap VFG 4 with VFG 3. Is the fault still present?
- If NO, replace VFG 4 and do close out.
- If YES, continue with next step.
- Replace ACPC.
- Do close out.