06/28/19
Message Overview:
Fault Message:
GCU4 [GLCR/DRIVE CIRCUIT]
Fault Code:
2424179LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 4 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) 4 has detected an internal failure related to the Generator Line Contactor Relay (GLCR) drive circuit, consequently resulting in a Generator 4 tripped off-line. GLCR/DRIVE circuit is responsible to energize the Generator Line Contactor Relay, within the GCU. The GLCR, once energized, provides the 28 VDC to the GLC located in the AC Power Center (ACPC).
Possible Causes:
- Generator Control Unit (GCU) 4 (A59)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Replace GCU 4.
NOTE: Use PMAT to monitor the fault on GCU. - Do close out.