Message Overview:
Fault Message:
GEN4 ROTOR DIODE FAILURE
Fault Code:
2424199LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 4 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Continuous monitoring in Generator Control Unit (GCU) 4 has detected an open circuit on the Rotor Diode of Variable Frequency Generator (VFG) 4, consequently resulting in Generator 4 being tripped off-line or not come on-line.
Possible Causes:
- Generator Control Unit (GCU) 4 (A59)
- Variable Frequency Generator (VFG) 4 (G4)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in the CAIMS via the fault messages page.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 4 with GCU 3 (physically or using the GCU patch cable). Is the fault still present?
- If NO, replace GCU 4 and do close out.
- If YES, continue with next step.
- Replace VFG 4.
- Do close out.