Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/27/24

Message Overview:

Fault Message:

GEN4 DRIVE SHAFT FAIL/INVALID % N2

Fault Code:

2424200LPS

Associated CAS:

GEN 4 FAIL
(Advisory)

Reporting LRU: Variable Frequency Generator (VFG) 4
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

Variable Frequency Generator (VFG) 4 has tripped off-line or will not come on-line.

Possible Causes:

  • Variable Frequency Generator (VFG) 4 (G4)
  • Generator Control Unit (GCU) 4 (A59)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: 

  • AW700-24-0598 - Variable Frequency Generator (VFG) GL511-1103-9 - Failure

Full Throttle Blog/Forum Articles/Infoservice/Newsletter:

Flight Operation Notifications Manual (FONM): None

NOTES:

  • Prior to T/S procedures, perform a visual of generator 4 for heat distress. Confirm if the heat exchanger is blocked with FOD.
  • A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).

  • The GCU NVMs can only be downloaded at position #2 or #3.

Quick Links:

Removal of the Variable Frequency Generators (VFG) AMM 24-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Variable Frequency Generators (VFG) AMM 24-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Access CAIMS and check if the following faults are active:

    • 2424124LPS - GEN4 [DIFF PROTECTION FEEDER]
    • 2424126LPS - GEN4 OIL OVERTEMP FAULT

    Inspect the VFG for the following:

    • VFG oil filter bypass indicator tripped, and/or
    • Metal particles in the oil lines, and/or
    • VFG end frame cracked or breached, and/or
    • Oil sight glass cracked

    1. If there is a combination of the listed CAIMS active fault and VFG condition(s) perform RIL GX-0198
    2. If there is NO combination, continue with next step.

  2. Do a visual inspection of the VFG. Is the drive shaft broken or sheared?

    1. If YES, investigate the cause and replace VFG 4.
    2. If NO, continue with next step.

  3. Interchange the GCU 4 with GCU 2 (physically or using the GCU patch cable).
    NOTE: Use CAIMS to monitor the fault on GCU.

    1. If system checks are good, replace GCU 4 and do close out.
    2. If fault remains, continue with next step.

  4. Disconnect VFG 4 connector G4P1 and GCU 4 connector A59P1. Do a continuity check as follows:

    From To Result
    A59P1-E Ground
    A59P1-F Ground
    A59P1-G Ground

    1. If there is continuity, repair defective wiring as required.
    2. If there is NO continuity, continue with next step.

  5. Do a continuity check between GCU 4 and VFG 4 as follows:

    From To Result
    A59P1-E G4P1-G
    A59P1-F G4P1-C
    A59P1-G G4P1-L

    1. If there is continuity, continue with next step.
    2. If there is NO continuity, repair defective wiring as required.

  6. Interchange VFG 4 with VFG 3.

    1. If system checks are good, replace VFG 4 and do close out.
    2. If fault remains, continue with next step.

  7. Disconnect ACPC connector A54P2 and GCU 4 connector A59P2. Perform wiring check between A59P2 and A54P2 as follow:

    From To Result
    A59P2-9 A54P2-a
    A59P2-15 A54P2-b

    1. If wiring checks are not good, repair defective wiring and do close out.
    2. If wiring checks are good, continue with next step.

  8. Replace ACPC.
  9. Do close out.