06/28/19
Message Overview:
Fault Message:
GCU4 [PROG PIN 1 SENSE]
Fault Code:
2424216LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 4 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) 4 has detected an internal failure related to its pin 1 programming sensing circuit and consequently Generator 4 trips off-line.
GCU uses 4 programming pins (0, 1, 2 and PAR (parity)) to determine its position (GCU1, GCU2, GCU3, GCU4 and Auxiliary Power Unit Generator Control Unit (APUGCU)). The GCU uses the odd parity system to determine if the programming pins are valid.
Possible Causes:
- Generator Control Unit (GCU) 4 (A59)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The GCU NVMs can only be downloaded at position #2 or #3.
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU4 and APU GCU into position 2 or 3 (for troubleshooting only).
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Replace GCU 4.
NOTE: Use PMAT to monitor the fault on GCU. - Do close out.