Message Overview:
Fault Message:
GCU4 [GEN CURRENT LIMIT INHIB]
Fault Code:
2424232LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 4 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Generator Control Unit (GCU) 4 detects the current limit inhibit discrete for 5 Sec without the logic signal ±15 V supply.
Possible Causes:
- Generator Control Unit (GCU) 4 (A59)
- AC Power Center (ACPC) (A54)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform a continuity check between GCU 4 and ground as follows:
From To Result A59P2-46 Ground - If there is no continuity, go to step 3.
- If there is continuity, continue with next step.
- Swap the GCU 4 with GCU 3 (physically or using the GCU patch cable).
- If system checks are good, replace GCU 4 and do close out.
- If fault remains, continue with next step.
- Remove all 3 PLCs inside the ACPC.
- Perfom a continuity check between ACPC and ground as follows:
From To Result A54P2-n Ground - If there is continuity, go to step 6.
- If there is no continuity, continue with next step.
- Perform a wiring check (shorted to ground= failure) between ACPC and GCU 4 as follows:
From To Result A54P2-n A59P2-46 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace ACPC.
- Do close out.