Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

GCU4 PIN PROG/SENSE FAULT

Fault Code:

2424251LPS

Associated CAS:

None

Reporting LRU: Generator Control Unit (GCU) 4
System Description: 24-21-00
Schematic Diagram: 24-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-21-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Generator Control Unit (GCU) 4 has detected a pin programming/sense fault, consequently resulting in Generator 4 being tripped off-line or not come on-line.

Possible Causes:

  • Generator Control Unit (GCU) 4 (A59)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCU 1, GCU 2, GCU 3, GCU 4 and the APU GCU into a different position (for troubleshooting only). You can monitor the GCU faults in the CAIMS via the fault messages page.

Quick Links:

Removal of the Generator Control Units (GCU) AMM 24-24-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Generator Control Units (GCU) AMM 24-24-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Disconnect GCU 4 connector A59P2. Use the table below to make sure that the program pins are wired properly:

    APU GCU GCU 1 GCU 2 GCU 3 GCU 4
    Prog pin 0
    P2-18
    to
    P2-34 (Gnd)
    Open Open Connected Open Connected
    Prog pin 1
    P2-27
    to
    P2-43 (Gnd)
    Connected Connected Open Open Connected
    Prog pin 2
    P2-17
    to
    P2-35 (Gnd)
    Open Connected Connected Connected Open
    Parity pin
    P2-26
    to
    P2-44 (Gnd)
    Open Connected Connected Open Connected

    1. If checks do not match the table, repair defective wiring and do close out.
    2. If all checks are good, continue with next step.

  2. Replace the GCU 4.
  3. Do close out.