Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

ACPC SSPC PWR CARD5 (A6)/L RECR FAN

Fault Code:

2451324ACP

Associated CAS:

ELEC SYS FAULT
(Advisory)

Reporting LRU: AC Power Center (ACPC) Solid State Power Converter (SSPC)
System Description: 21-20-00
24-50-00
Schematic Diagram: 24-51-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
24-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The AC Power Center (ACPC) Solid State Power Converter (SSPC) power card has detected a failure with the initialization of the AC SSPCs, the control logic circuitry and/or the load.

Possible Causes:

  • AC Power Center (ACPC) Solid State Power Converter (SSPC) 5
  • AC Power Center (ACPC) (A54)
  • Left Recirculation Fan
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

  • If the FAN is inoperative without CAIMS message and breaker is IN, check wires between BLEED AIR CONTROL PANEL and EMS CDU 1 and 2
  • If the breaker always tripping without CAIMS message, check for a short circuit between the LEFT RECIRC FAN and the SSPC #5

Quick Links:

Removal of the Recirculation Fan and Check Valves AMM 21-21-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Recirculation Fan and Check Valves AMM 21-21-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Solid-State Power Controller AMM 24-51-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Solid-State Power Controller AMM 24-51-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SSPC 5 with SSPC 10. Monitor the R AFT BOOST PUMP.

    1. If system checks are good, replace SSPC 5 card and do close out.
    2. If fault remains, continue with next step.

  2. Disconnect the L RECIRC FAN and remove the SSPC card 5. Perform continuity check for open circuits between the connections that follows:

    From To Result
    SSPC 5 P160-25 B17P1-C
    SSPC 5 P160-28 B17P1-B
    SSPC 5 P160-31 B17P1-A

    1. If there is no continuity, repair the defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  3. Perform continuity check between the connections that follows:

    From To Result
    SSPC 5 P160-25 Ground
    SSPC 5 P160-28 Ground
    SSPC 5 P160-31 Ground
    SSPC 5 P160-25 SSPC 5 P160-28
    SSPC 5 P160-25 SSPC 5 P160-31
    SSPC 5 P160-28 SSPC 5 P160-31

    1. If the fault follows, replace the defective components and do close out.
    2. If there is continuity, go to step 5.
    3. If there is no continuity, continue with next step.

  4. Swap RECIRC FAN with another RECIRC FAN.

    1. If system checks are good, replace defective RECIRC FAN and do close out.
    2. If fault remains, continue with next step.

  5. Disconnect connector A54P5. Repeat steps 3.

    1. If there is no continuity, repair defective aircraft wiring as required and do close out.
    2. If there is continuity, continue with next step.

  6. Replace ACPC.
  7. Do close out.