06/28/19
Message Overview:
Fault Message:
ACPC SSPC PWR CARD10(A23)/R AFT PMP
Fault Code:
2451329ACP
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) Solid State Power Converter (SSPC) |
| System Description: | 24-50-00 28-21-00 |
| Schematic Diagram: | 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] 28-21-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The AC Power Center (ACPC) Solid State Power Converter (SSPC) power card has detected a failure with the initialization of the AC SSPCs, the control logic circuitry and/or the load.
Possible Causes:
- AC Power Center (ACPC) Solid-State Power Controller (SSPC) 10
- Right Aft Boost Pump
- AC Power Center (ACPC) (A54)
- Associate Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
- If the pump is inoperative without CAIMS message and breaker is IN, check wires between FUEL CONTROL PANEL, SLC #4 and THROTTLE QUADRANT
- If the breaker is always tripping without CAIMS message, check for a short circuit between the RIGHT AFT BOOST PUMP and the SSPC #10
Quick Links:
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Boost-Pump Cartridges | AMM 28-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Boost-Pump Cartridges | AMM 28-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SSPC 10 with SSPC 15 and monitor the AVIONICS FAN.
- If system checks are good, replace SSPC 10 card and do close out.
- If fault remains, continue with next step.
- Disconnect the R AFT BOOST PUMP connector B23P1 and remove the SSPC 10 card. Perform continuity check between the connections that follows:
From To Result SSPC 10 P420-25 B23P1-A SSPC 10 P420-18 B23P1-B SSPC 10 P420-31 B23P1-C - If there is no continuity, repair the defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform continuity check between the connections that follows:
From To Result SSPC 10 P420-25 Ground SSPC 10 P420-18 Ground SSPC 10 P420-31 Ground SSPC 10 P420-25 SSPC 10 P420-18 SSPC 10 P420-25 SSPC 10 P420-31 SSPC 10 P420-18 SSPC 10 P420-31 - If there is no continuity, replace R AFT BOOST PUMP and do close out.
- If there is continuity, continue with next step.
- Disconnect connector A54P1 and repeat step 3.
- If there is no continuity, repair aircraft wiring interface as required and do close out.
- If continuity, continue with next step.
- Replace ACPC.
- Do close out.