Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

ACPC SSPC PWR CARD11(A24)/R XFR PMP

Fault Code:

2451330ACP

Associated CAS:

ELEC SYS FAULT
(Advisory)

Reporting LRU: AC Power Center (ACPC) Solid State Power Converter (SSPC)
System Description: 24-50-00
28-22-00
Schematic Diagram: 24-51-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
28-22-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
28-41-08 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The AC Power Center (ACPC) Solid State Power Converter (SSPC) power card has detected a failure with the initialization of the AC SSPCs, the control logic circuitry and/or the load.

Possible Causes:

  • AC Power Center (ACPC) Solid−State Power Controller (SSPC) 11
  • Right Center Transfer Pump
  • AC Power Center (ACPC) (A54)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

  • If the pump is inoperative without CAIMS message and breaker is IN, check wires between FMQGC, FUEL CONTROL PANEL and EMS CDU 1 and 2
  • If the breaker is always tripping without CAIMS message, check for a short circuit between the RIGHT TRANSFER PUMP and the SSPC #11

Quick Links:

Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC)
Solid-State Power Controller
AMM 24-51-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC)
Solid-State Power Controller
AMM 24-51-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Center Transfer-Pump Canisters AMM 28-22-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Center Transfer-Pump Canisters AMM 28-22-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SSPC 11 with SSPC 10 and monitor the R AFT BOOST PUMP.

    1. If system checks are good, replace SSPC 11 card and do close out.
    2. If fault remains, continue with next step.

  2. Disconnect the R CENTER TRANSFER-PUMP connector B33P1 and remove the SSPC 11 card. Perform continuity check between the connections that follows:

    From To Result
    SSPC 11 P430-25 B33P1-A
    SSPC 11 P430-18 B33P1-B
    SSPC 11 P430-31 B33P1-C

    1. If there is no continuity, repair the defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  3. Perform continuity check between the connections that follows:

    From To Result
    SSPC 11 P430-25 Ground
    SSPC 11 P430-18 Ground
    SSPC 11 P430-31 Ground
    SSPC 11 P430-25 SSPC 11 P430-18
    SSPC 11 P430-25 SSPC 11 P430-31
    SSPC 11 P430-18 SSPC 11 P430-31

    1. If there is no continuity, replace R CENTER TRANSFER-PUMP and do close out.
    2. If there is continuity, continue with next step.

  4. Disconnect connector A54P1. Repeat step 4.

    1. If there is no continuity, repair aircraft wiring interface as required and do close out.
    2. If continuity, continue with next step.

  5. Replace ACPC.
  6. Do close out.