background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

ACPC SSPC PWR CARD12(A25)/R LDG LTS

Fault Code:

2451331ACP

Associated CAS:

ELEC SYS FAULT
(Advisory)

Reporting LRU: AC Power Center (ACPC) Solid-State Power Controller (SSPC)
System Description: 24-50-00
33-41-00
Schematic Diagram: 24-51-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-54-15 [ Global Express ]  [ G5000 ]  [ Global XRS ]
24-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
33-40-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
33-41-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
33-41-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The AC Power Center (ACPC) Solid-State Power Controller (SSPC) power card has detected a failure with the initialization of the AC SSPCs, the control logic circuitry and/or the load.

Possible Causes:

  • AC Power Center (ACPC) Solid-State Power Controller (SSPC) 12
  • Right Taxi Light (DS30)
  • Right Wing Landing Light (DS30)
  • Satellite Communication (SATCOM) Fan Converter (B65)
  • AC Power Center (ACPC) (A54)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

  • If the RIGHT TAXI LIGHT or the RIGHT WING LANDING LIGHT is inoperative without CAIMS message and breakers is IN, check wires between EMS CDUs and external lighting control panel
  • If the breaker is always tripping without CAIMS message, check for a short circuit between the RIGHT TAXI LIGHT, RIGHT WING LANDING LIGHT, SATCOM FAN converter and the SSPC #12

Quick Links:

Removal of the SATCOM High-Power-Amplifier (HPA) Fan Converter AMM 21-54-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the SATCOM High-Power-Amplifier (HPA) Fan Converter AMM 21-54-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC)
Solid-State Power Controller
AMM 24-51-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC)
Solid-State Power Controller
AMM 24-51-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Wing Landing/Taxi Lights AMM 33-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Wing Landing/Taxi Lights AMM 33-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SSPC 12 with SSPC 10 and monitor the R AFT BOOST PUMP.

    1. If system checks are good, replace SSPC 12 card and do close out.
    2. If fault remains, continue with next step.

  2. Disconnect the R WING LANDING/TAXI LIGHT assembly connector DS30P1, SATCOM HPA Fan Converter connector B65P1 and remove the SSPC 12 card. Perform continuity check between the connections that follows:

    From To Result
    SSPC 12 P440-25 DS30P1-A
    SSPC 12 P440-28 DS30P1-C
    SSPC 12 P440-31 B65P1-A

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  3. Perform continuity check for open circuits between the connections that follows:

    From To Result
    SSPC 12 P440-25 Ground
    SSPC 12 P440-28 Ground
    SSPC 12 P440-31 Ground
    SSPC 12 P440-25 SSPC 12 P440-28
    SSPC 12 P440-25 SSPC 12 P440-31
    SSPC 12 P440-28 SSPC 12 P440-31

    1. If there is no continuity, replace the R WING LANDING/TAXI LIGHT assembly or the SATCOM Fan Converter assembly as required and do close out.
    2. If there is continuity, continue with next step.

  4. Disconnect connector A54P1 and repeat step 3.

    1. If there is no continuity, repair aircraft wiring interface as required and do close out.
    2. If there is continuity, continue with next step.

  5. Replace ACPC.
  6. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.